What should I do if the floor heating is thick but not hot? Summary of popular solutions across the network in the past 10 days
As winter approaches, the issue of underfloor heating has become a hot topic on the Internet recently. Many users have reported that the floor heating is too thick, resulting in poor heat dissipation. This article will combine the discussion data from the entire network in the past 10 days to provide you with structured analysis and solutions.
1. Analysis of the popularity of floor heating issues across the entire network (last 10 days)

| platform | Amount of related topics | Main focus of discussion |
|---|---|---|
| Douyin | 23,000 items | Floor heating backfill thickness standard |
| little red book | 18,000 articles | DIY solution sharing |
| Zhihu | 460 questions | Professional technical analysis |
| Baidu Tieba | 1200 posts | Troubleshooting experience |
2. Three main reasons why the floor heating is thick and not hot.
According to feedback from engineers and users across the network, the main reasons can be summarized as follows:
| Ranking | Reason | Proportion |
|---|---|---|
| 1 | The backfill layer is extremely thick (>5cm) | 42% |
| 2 | Improper insulation material | 35% |
| 3 | Pipe spacing is too large | 23% |
3. Six proven solutions
1.Adjust water supply temperature: It is recommended to gradually increase to 55-60℃, but not exceed 65℃ to prevent damage to the pipeline
2.Optimize system pressure: Keep the working pressure between 1.5-2bar. Insufficient pressure will lead to poor hot water circulation.
3.Check the backfill layer: The ideal thickness is 3-5cm. If it is too thick, partial disassembly or use of thermally conductive materials should be considered.
| Material | Thermal conductivity (W/m·K) | Applicable scenarios |
|---|---|---|
| pisolite concrete | 1.2-1.5 | Standard backfill |
| Gypsum-based material | 0.5-0.8 | Thin layer repair |
| Thermal mortar | 1.8-2.2 | Renovate and strengthen |
4.Clean pipes: Professional cleaning is required every 2-3 years. 1mm of scaling will cause the room temperature to drop by 3-5°C.
5.Add reflective film: Installing aluminum foil reflective film on top of the insulation layer can increase thermal efficiency by 15%-20%
6.System transformation: In extreme cases, the pipes need to be re-routed. It is recommended that the spacing be adjusted to 15-20cm.
4. Comparison of user actual measurement results
| solution | Implementation cost | Warming effect | duration |
|---|---|---|---|
| Increase water temperature | 0 yuan | +2-3℃ | Instant |
| Clean pipes | 300-800 yuan | +3-6℃ | 2-3 years |
| Replace backfill layer | 2000+ yuan | +5-8℃ | long term |
5. Special reminder from experts
1. It takes 24-48 hours after the floor heating is turned on to reach its optimal condition. Do not adjust it frequently.
2. The thermal conductivity of solid wood flooring is only 0.15-0.2. It is recommended to use ceramic tiles instead (thermal conductivity 1.0-1.5)
3. The latest data shows that using intelligent temperature control systems can save 20%-30% of energy, and the investment payback period is about 2 years.
Through the above structured analysis and solutions, we hope to help you effectively solve the problem of thick and tepid floor heating. It is recommended to try a low-cost solution first, and then consider system modification if it is still not ideal. Heating in winter is no small matter, safety and efficiency are the most important!